Advantage
of Cooling with Performance and Value...
|
Introducing
Gryphon Fans |
 |
|
AC
Fans Standard Features:
- Operating
Temperature: -10°C to +70°C
- Storage
Temperature: -40°C
to +80°C
- Termination:
Via two off terminal pins
- Impeller:
Black, UL94-VO rated thermoplastic
- Housing:
Black, Aluminum construction
- Airflow
Direction: intake over the fan struts
|
AC
Fans Benefits:
- High
performance, low cost fan minimizing design and inventory
costs
- Tolerance
of ± 10% on input voltage, making the fan suitable
for use worldwide
- Two
ball bearing systems per fan, providing high lifetime
reliability
|
| . |
Cat.
No. |
Rated
Voltage
VAC |
Operating
Voltage Range
VAC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Lead
Type |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 120
x 120 x 38 mm |
 |
GAA1238-115BB
|
115-50/60Hz |
81-125 |
0.30 |
24 |
3000 |
188.70 |
111 |
9.3 |
0.37 |
44 |
Connector |
560g
1.23lbs |
Order |
| 80
x 80 x 38 mm |
 |
GAA8038-115BB
|
115-50/60Hz |
81-125 |
0.20 |
14 |
3000 |
49.3 |
29 |
5 |
0.2 |
34 |
Connector |
340g
0.75lbs |
Order |
|
 |
|
DC
Fans Standard Features:
- Operating
Temperature: -10°C to +70°C
- Storage
Temperature: -40°C
to +80°C
- The
motor is impedance protected to prevent burn-out if
obstructed
- Impeller:
Black, UL94-VO rated thermoplastic
- Housing:
Black,UL94-VO rated thermoplastic
- Airflow
Direction: intake over the fan struts
|
DC
Fans Benefits:
- High
performance, low cost fan minimizing design and inventory
costs
- Integral
Open Collector tachometer wire supplied as standard,
for optional use, eliminating the need for a custom
alternative fan
- Two
ball bearing systems per fan, providing high lifetime
reliability
-
For GDA1225-12BB and GDA1225-24BB: Auto-restart feature,
once obstruction removed
|
| . |
Cat.
No. |
Rated
Voltage
VDC |
Operating
Voltage Range
VDC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Tach |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 120
x 120 x 25 mm (Termination: 200mm (7.87")
Leadwires; 24 AWG, UL 1007; Red - Positive; Black
- Negative; White - Tachometer) |
 |
GDA1225-12BB
|
12 |
6.0-13.8 |
0.40 |
4.8 |
2400 |
117.91 |
69.36 |
3.84 |
0.15 |
39.08 |
Yes |
164g
0.36lbs
|
Order |
|
GDA1225-24BB
|
24 |
12.0-27.6 |
0.35 |
8.4 |
2400 |
117.91 |
69.36 |
3.84 |
0.15 |
39.08 |
Yes |
164g
0.36lbs |
Order |
| . |
Cat.
No. |
Rated
Voltage
VDC |
Operating
Voltage Range
VDC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Tach |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 40
x 40 x 10 mm (Termination: 240mm (9.44")
Leadwires; 28 AWG, UL 1007; Red - Positive; Black
- Negative; White - Tachometer) |
 |
GDA4010-12BB
|
12 |
6.0-13.8 |
0.09 |
1.08 |
7000 |
13.14 |
7.73 |
3.86 |
0.15 |
30.48 |
Yes |
16g
0.35lbs
|
Order |
|
GDA4010-24BB
|
24 |
12.0-27.6 |
0.09 |
2.16 |
7000 |
13.14 |
7.73 |
3.86 |
0.15 |
30.48 |
Yes |
16g
0.35lbs
|
Order |
| . |
Cat.
No. |
Rated
Voltage
VDC |
Operating
Voltage Range
VDC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Tach |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 40
x 40 x 20 mm (Termination: 240mm (9.44")
Leadwires; 28 AWG, UL 1007; Red - Positive; Black
- Negative; White - Tachometer) |
 |
GDA4020-12BB
|
12 |
6.0-13.8 |
0.12 |
1.44 |
8000 |
14.81 |
8.73 |
5.87 |
0.23 |
30.92 |
Yes |
29g
0.06lbs
|
Order |
|
GDA4020-24BB
|
24 |
12.0-27.6 |
0.07 |
1.68 |
8000 |
14.81 |
8.73 |
5.87 |
0.23 |
30.92 |
Yes |
29g
0.06lbs
|
Order |
| . |
Cat.
No. |
Rated
Voltage
VDC |
Operating
Voltage Range
VDC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Tach |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 60
x 60 x 25 mm (Termination: 230mm (9.06")
Leadwires; 26 AWG, UL 1007; Red - Positive; Black
- Negative; White - Tachometer) |
 |
GDA6025-12BB
|
12 |
6.0-13.8 |
0.14 |
1.68 |
4000 |
32.73 |
19.25 |
4.29 |
0.17 |
26.1 |
Yes |
62g
0.13lbs
|
Order |
|
GDA6025-24BB
|
24 |
12.0-27.6 |
0.14 |
3.36 |
4000 |
32.73 |
19.25 |
4.29 |
0.17 |
26.1 |
Yes |
62g
0.13lbs
|
Order |
| . |
Cat.
No. |
Rated
Voltage
VDC |
Operating
Voltage Range
VDC |
Rated
Current
Amps |
Rated
Input Power Watts |
Speed
RPM |
Max.
Airflow |
Max.
Air Pressure |
Noise
dBa |
Tach |
Weight |
Shop
Online |
| m3/hour |
CFM |
mm
H2O |
in
H2O |
| 80
x 80 x 25 mm (Termination: 220mm (8.66")
Leadwires; 26 AWG, UL 1007; Red - Positive; Black
- Negative; White - Tachometer) |
 |
GDA8025-12BB
|
12 |
6.0-13.8 |
0.17 |
2.04 |
3000 |
60.32 |
35.48 |
3.34 |
0.13 |
30.8 |
Yes |
76g
0.17lbs
|
Order |
|
GDA8025-24BB
|
24 |
12.0-27.6 |
0.15 |
3.60 |
3000 |
60.32 |
35.48 |
3.34 |
0.13 |
30.8 |
Yes |
76g
0.17lbs
|
Order |
|