The Littelfuse POWR-PRO
System of Fuses
gives you all
the fuses you need for complete
circuit protection coverage
while reducing inventory and
controlling costs.
The POWR-PRO System will:
- Provide superior current-limiting protection with innovative, tested
designs to prevent or reduce electrical system damage.
- Reduce inventory by standardizing system protection.
- Provide visual blown fuse indication with LLSRK_ID, and JTD_ID
Indicator® fuses.
- Reduce fuse replacement downtime with simple color coded fuse labels.
See for yourself why the POWR-PRO System gives you the widest range
of circuit protection available today when compared to other systems.
Minimize Arc-Flash Hazards
Some of the factors that determine the severity of an Arc-Flash
are the magnitude of the fault current and the time the current is
allowed to flow. Current-limiting fuses applied within their currentlimiting
range minimize the current flow and clear the fault in
0.00833 seconds or less. The more current-limiting the device
and the faster it clears the fault minimizes Arc-Flash hazards and
potentially reduces the amount of personal protective equipment
(PPE) required. Using Littelfuse POWR-PRO Fuses will not only
minimize Arc-Flash hazards with superior current limitation, but also
provide maximum protection to equipment.
One of the quickest and easiest ways to reduce Arc-Flash hazards is to
replace UL Class H, K5, and Class RK5 fuses with POWR-PRO currentlimiting
Class RK1 or Class J fuses. For a given current and voltage
rating, Class H, K5, RK5, and RK1 fuses are the same physical size.
Therefore, it is easy to upgrade to better fuse protection and increased
safety. To insure that only the most current-limiting fuse is used, it
is recommended to change fuse clips to a rejection style for Class R
or Class J fuses. Class J fuses provides the best option by assuring
non-interchangeability with non-current-limiting fuses. Whichever
your choice, the equipment should be labeled to inform maintenance
personnel of the proper fuse replacement. The Littelfuse MROplus™
Program can assist with analyzing and upgrading from non-currentlimiting
fuses.
Green label fuses provide all
the inventory you need for:
- Superior current-limitation from
1/10 – 6000 amperes.
- Type 2 “No Damage”
coordination with NEMA and
IEC motor circuits.
- Blown fuse indication
(LLSRK_ID and JTD_ID).
- Compact protection for motor
circuits (JTD, JTD_ID, and
CCMR).
- 300,000 AIR to meet future
trends toward higher available
short circuit currents.
|

For more information, call Electro Sonic at 1.800.56.SONIC |