The 169G is an isolating transformer designed to provide galvanic isolation and multiple secondary voltage outputs from a 115V, 60Hz primary input at 500VA capacity. It features multiple selectable secondary taps providing output voltages of 90V, 100V, 110V, 115V, 120V, and 130V, with secondary no-load voltages ranging from 93.38V to 133.7V (±2% tolerance). The transformer has a primary excitation current of 866mA maximum at 115V, 60Hz, and includes high-voltage isolation testing at 1500V, 60Hz between primary and secondary windings. With all leads extending 8 inches minimum and compact dimensions (4.313" height, 5.435" width, 3.750" depth), this transformer is ideal for laboratory equipment, medical devices, and industrial control systems requiring isolated power supplies with flexible voltage selection.