PAD002-T764111S
BournsPush-Pull Insulation Transformer -5V - 1:1.1 - 1.5W ...
DESCRIPTION
PAD002-T764111S is a push-pull isolation transformer from the PAD00x-T764 series designed for isolated power supply applications in industrial and renewable energy systems. The transformer features a primary inductance of 475 µH at 100 kHz with a 1:1.1 turns ratio, providing 3100 VAC isolation voltage between primary and secondary windings. It operates continuously at 400 Vrms functional insulation per IEC 62368 with a maximum current rating of 350 mArms and operates reliably across a temperature range of -40°C to +125°C. The device exhibits low profile and small size (7.10 x 6.55 x 4.0 mm) with a maximum volt-microsecond rating of 11 V-µs, making it ideal for isolated RS-485/RS-232 power supplies, industrial automation, AC motor drives, smart metering, and solar inverters.
Search Keywords: PAD002T764111S
SPECIFICATIONS
IN STOCK: 800
Ships today, if you order in
MOQ for In Stock Qty: 250
MOQ for out of Stock Qty: 250
Factory Lead-Time 20 Weeks
English
French